The component used to switch the heat pump unit between the heating and cooling modes of operation is the ____.


A) four-way valve
B) bi-valve
C) two-way valve
D) switching valve

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

When oil or gas auxiliary heat is used with a heat pump, the heat pump indoor coil must be located  ____________________ of the oil or gas heat exchanger.

Correct Answer

verifed

verified

The coil of the air-to-air heat pump system that is the indoor unit is known as the ____________________ in the heating mode.

Correct Answer

verifed

verified

Some heat pump systems when not capable of meeting the heating needs of the structure are equipped with second-stage heat, called ____________________.

Correct Answer

verifed

verified

The larger line in an air-to-air split-system heat pump is known as the ____ line.


A) vapor
B) liquid
C) transient
D) gas

E) C) and D)
F) A) and C)

Correct Answer

verifed

verified

When a heat pump is added to an electric furnace, the indoor coil must be located after the ____________________ strips.

Correct Answer

verifed

verified

Most heat pump systems are designed to operate in the heating mode when the solenoid is not energized. This is referred to as "____________________ in the heating mode".

Correct Answer

verifed

verified

An air-to-air heat pump ____ heat from the outside air and deposits it in the conditioned space.


A) adds
B) removes
C) creates
D) restricts

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

B

The coil of the air-to-air heat pump system that is the indoor unit is known as the ____________________ in the cooling mode.

Correct Answer

verifed

verified

When a compressor is changed, the four-way valve also must be changed.

A) True
B) False

Correct Answer

verifed

verified

False

In heat pump systems the sensing bulb is typically exposed to high temperatures and could rupture the valve diaphragm. For this reason, a(n) ____________________ TVX is usually used.

Correct Answer

verifed

verified

vapor-char...

View Answer

A(n) ____________________ thermostatic expansion valve has a check valve built into the body of the TXV.

Correct Answer

verifed

verified

bi-directi...

View Answer

In the emergency heat mode, the auxiliary heat source becomes the primary heat source because of heat pump failure.

A) True
B) False

Correct Answer

verifed

verified

The term ____________________ indicates the source of heat while the system is operating in the heating mode and the medium that is ultimately being treated.

Correct Answer

verifed

verified

air-to-air...

View Answer

The smaller line in an air-to-air split-system heat pump is known as the ____ line.


A) gas
B) vapor
C) solid
D) liquid

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

D

What prevents cold air from being circulated to the heated space during the defrost cycle?


A) The auxiliary heater turns on to "temper" the air.
B) All of the dampers close automatically.
C) The indoor fan motor turns off.
D) Both a and b are correct.

E) C) and D)
F) A) and C)

Correct Answer

verifed

verified

It is common for the outdoor unit to ice-up when the heat pump is operated in the cooling mode.

A) True
B) False

Correct Answer

verifed

verified

The ____________________ is a four-port valve that has a slide mechanism in it.

Correct Answer

verifed

verified

four-way r...

View Answer

The lowest outside air temperature at which the heat pump system can satisfy the heating needs of the structure without requiring auxiliary heat is called the ____________________.

Correct Answer

verifed

verified

What is it meant by the terminology "time or temperature terminated" defrost cycle?

Correct Answer

verifed

verified

It means that either...

View Answer